0E00002D: The following function is not supported: '...'.
An attempt was made to perform a function that is not supported. The required action depends upon the message content. The following list shows the messages where appropriate actions can be taken.
For all other messages a process trace must be created and sent to the technical support of your local Rocket Software representative.
- Batch Compare Record too long
- The data record size exceeds the specified maximum size.
Increase the value for 'Maximum RECORD/BLOCK-size' in setting 'Sizes'.
- No ADABAS Descriptor for Batch Compare
- A Batch Compare should be performed for an ADABAS source file. No descriptor has been specified for the file.
An ascending, unique descriptor with no NULL value must be specified for this table.
- ADABAS Descriptor with NULL-Value
- A descriptor has been specified to read an ADABAS file, however this descriptor contains NULL values.
Specify another unique and ascending descriptor that does not have NULL values.
- ADABAS Descriptor too long
- An ADABAS descriptor has been specified that exceeds the maximum length of 500.
Specify another descriptor.
- Non CICS-Log
- A file has been specified as a CICS Log, however the file is not a CICS Log.
Specify the correct file.
- CICS System Log
- An attempt has been made to process a CICS System Log as a CICS Log.
Specify the correct file.
- Unsupported Version of CICS
- An attempt has been made to process a CICS Log/Journal that has been created by a CICS version that is not supported. CICS TS as of version 1.3 for z/OS and CICS 2.3 and CICS TS 1.1.x for z/VSE are supported.
- Non asc. TS: ...
- During the processing of a CICS Journal time-stamps have been found that are not in ascending sequence. Processing is terminated.
- No Start of Task rec. found for Task(...)
- A task termination information has been found in a CICS Journal however no task start information is available.
- Input Type not supported
- An invalid input type has been specified.
Use the process wizard to open the process and select an input type from the list.
- Input DataSourceType not supported
- An input data source type has been specified that is not supported.
Use the process wizard to open the process and select an input data source type from the list.
- Input Stage invalid
- A file has been processed in the internal format however the header record is invalid.
Check whether the specified input file has been created in the internal format. Possibly select another file.
- Input Subsystem not supported
- A file has been read in the internal format however the header record is invalid.
Check whether the specified input file has been created in the internal format. Possibly select another file.
- Db2 RBA gap from restart RBA(...) to logical RBA(...)
- A gap has been found when processing Db2 RBAs. Processing is terminated to avoid the risk of losing data.
- Restartable sender is pool process, but receiver process is not LUW managed
- Option 'Restart after connection loss' has been activated in a sending process. This processing is only possible if the receiving process is capable to write information concerning a restart. This requires the LUW Manager to be active.
Activate the LUW Manager in the receiving process.
- Db2 RBA gap from restart RBA(...) to current RBA(...)
- A gap has been found when processing Db2 RBAs. Processing is terminated to avoid the risk of losing data.
- UPDATE Logrec for Non DATA CAPTURE Table DbSpaceNo(...) TableId(...)
- A Db2 table has been selected for processing, however this table does not have the DATACAPTURE attribute. Changes applied to this table cannot be processed.
Set the DATACAPTURE attribute for this table.
- POOL Output for external process
- An external process has been started with an input data source of 'CDC_POOL'.
This process can only be started under the control of an Agent.
- Non-Query type SQL Statement
- A statement has been specified for a Bulk-Transfer that does not create a result set or columns.
Correct the statement. Only SELECT statements can be used for the data source.
- Too many IDMS areas
- The maximum number of IDMS areas has been exceeded. A maximum of 100 areas can be processed.
- IMS: No corresponding GHx call for Command...
- During retrieval of pool records it has been detected that no previous 'Get Hold' call has been issued for a DELE or REPL command.
Activate the trace of the DBMS extension and reproduce the situation.
- More than ... Parent-Segments defined in...
- Too many parent segments have been defined. The maximum depth that can be processed is 256.
- Db2 Logrecs to Stage 2+ without PM_I.Db2xxx_SELECTION
- A process propagates Db2 log records to Stage 2 or 3 but no tables have been selected.
Open the process using the wizard and define selection criteria for Db2 tables.
- Db2 Logrecs without Agent-Link
- A process has been started that must connect to a Agent to process Db2.
Start the process under the control of an Agent or use parameter Agent= when starting the process.
- ScheduleProcess but no Agent
- A process has been defined to schedule another process when a certain event happens or a file has been closed. The process does not run under the control of an Agent.
Start the process under the control of an Agent or use parameter Agent= when starting the process.
- DATACOM BatchCompare without key name
- A process has been started that should perform a Batch Compare for a DATACOM table. A definition of a key is mandatory for this type of function.
Specify an ascending key without NULL values.
- MS SQL Server loader and output CCSID 1208
- A process has been started that should create the input for the SQL-Server Loader. 1208 (UTF-8) has been specified as output code page. The Loader of the MS-SQL Server does not support a data representation for multi byte code pages.
Specify an output code page of 1200 (UNICODE little endian) or specify a local code table.
- Uneven number of characters in MS SQL loader ROW/LINE delimiter string
- An uneven number of characters for the delimiter character has been specified for the SQL Loader. This is not allowed because the first half of the character string is used as field- and the second half is used as line-delimiter.
Specify an even number of characters for the delimiter character.
- Primary key too long
- The maximum length for the key value has been exceeded. Only keys with a length up to 500 can be processed.
- Too many key fields
- The maximum number of key fields has been exceeded. Only tables with up to 50 key fields can be processed.
- Too many defined DATACOM elements
- The maximum number of DATACOM elements have been exceeded. A maximum of up to 100 elements can be processed.
- Nested record types
- Multiple nested record types have been detected. This processing type is not allowed.
Change the structure file in a way, that no record types are nested.
- Nested REDEFINE
- Multiple nested redefined fields have been detected. This processing type is not allowed.
Change the structure file in a way, that no redefined fields are nested.
- Isolated REDEFINE=
- During the processing of a structure file the key word REDEFINE= has been detected (end indicator of a redefined field) however there is no start indicator.
Correct the structure file.
- Decompression of Db2 non-Data Capture Table(...)
- A Db2 table has been selected for processing, however this table does not have the DATACAPTURE attribute. Changes applied to this table cannot be processed.
Assign the DATACAPTURE attribute to this table.
- IDMS_KEY_CONNECT_NAME not defined
- For the resolution of OWNER-MEMBER relations and for the determination of the OWNER DBKEYs a connection must be defined that allows access to a relational OWNER table (ODBC, DRDA, ORACLE).
Specify this connection type.
- IDMS_KEY_CONNECT_TYPE not valid
- For the resolution of OWNER-MEMBER relations and for the determination of the OWNER DBKEYs a connection must be defined that allows access to a relational OWNER table (ODBC, DRDA, ORACLE).
Specify one of the three connection types.
- Field count mismatch for SQL Bulk in CDS(...)
- The structure file defined in exit CDC_ExitDBControl does not have the same number of fields as in the SQL query.
Recreate the structure file or change the SQL query so that the fields match.
- Field type mismatch for SQL Bulk in Field(...)
- The structure file defined in exit CDC_ExitDBControl has a different field type for the field shown in the message compared to the field in the query.
Recreate the structure file or change the SQL query so that the fields match.
- Field length mismatch for SQL Bulk in Field(...)
- The field referenced in the message of the structure file defined in exit CDC_ExitDBControl has a length different from the field in the query.
Recreate the structure file or change the SQL query so that the fields match.